Introduction
Technical drawings are the common language of engineering, used to convey design intent, manufacturing requirements and installation specifications without ambiguity. Computer-aided design (CAD) has transformed how drawings are made, and has also brought new challenges in standardisation and data management. This article summarises the CAD drawing standards commonly used in equipment documentation, helping design, manufacturing and construction teams communicate smoothly.
Drawing Types
General Arrangement (GA) Drawings
A GA drawing shows the overall layout and external interfaces of the equipment, including overall dimensions, nozzle locations and sizes, external structure, weight and centre of gravity, foundation requirements and maintenance clearances. It supports plant design, space planning and preliminary piping layout without exposing proprietary internal design. Scales are usually 1:10, 1:20 or 1:50, with the equipment shown on a single sheet where possible.
Detail Drawings
Detail drawings fully define each component for manufacture, with all dimensions, material specifications, manufacturing tolerances, surface roughness and machining notes. Each part has its own drawing, with sectional and enlarged detail views. Complex assemblies may use several drawings to show each assembly stage.
Assembly Drawings
Assembly drawings show how components fit together. Exploded views separate parts along the assembly axis, with leader lines linked to the parts list. Sectional views reveal internal structure and part relationships. The bill of materials (BOM) lists item numbers, descriptions, quantities and material specifications.
Piping and Instrumentation Diagrams (P&ID)
A P&ID shows process flow and control system design: equipment uses standard symbols defined in ISA-5.1 or ISO 10628; different line types indicate pipe class and fluid; control loops, sensors and final control elements are shown to ISA standards; and process data such as flow, pressure, temperature and composition is noted.
Foundation Drawings
Foundation drawings detail equipment support requirements, including anchor bolt layout (bolt pattern dimensions, sizes and projection), load information such as static and dynamic loads, moments and shear forces, grouting details and acceptance criteria, and elevation views showing levels and baseplate details.
CAD Drawing Standards
ISO Standards
ISO 128 (Technical drawings, general principles of presentation) sets basic rules for line types, scales, views and sections. ISO 5457 specifies sheet sizes (A0 to A4), title blocks and layout. ISO 7200 specifies data fields and arrangement of title blocks. ISO 13715 specifies how to indicate edges of undefined shape.
ASME Standards
ASME Y14.100 (Engineering drawing practices) is a comprehensive standard covering multiview drawings, dimensioning and tolerancing. ASME Y14.5 (Dimensioning and tolerancing) defines the symbols, definitions and application rules of geometric dimensioning and tolerancing (GD&T). ASME Y14.24 defines the types and uses of engineering drawings.
Industry-Specific Standards
API 686 (Recommended practice for machinery installation and installation design) guides installation drawings and documents for rotating equipment. TEMA standards set drawing conventions for shell and tube heat exchangers. HI standards (Hydraulic Institute) provide standards and recommended practices for pump drawings.
Line Types and Line Weights
Standard Line Types
| Line type | Line weight | Use and key points |
|---|---|---|
| Thick continuous line (visible outline) | 0.5–0.7 mm | Shows visible edges and outlines in the main view |
| Medium dashed line (hidden outline) | 0.3–0.5 mm | Shows hidden features, dashes 3–5 mm long with 1–2 mm gaps |
| Thin chain line (centre line) | 0.25–0.35 mm | Shows axes of symmetry and rotation, alternating 20–30 mm long dashes and 3–5 mm short dashes |
| Thin continuous line (dimension line) | 0.25–0.35 mm | Ends in arrows or dots at the extension lines |
| Thin continuous line (hatching) | Thin | Shows cut surfaces, usually at 45° with 2–3 mm spacing |
| Thin continuous line (construction line) | Very thin | Used while drawing, usually removed from the final drawing |
Layer Organisation
Modern CAD manages graphic elements with layers: visible, hidden and centre lines go on object layers; dimensions and annotations on a dedicated dimension layer; general notes, title block and labels on a text layer; hatching and fills on a hatch layer; construction geometry on a reference layer; and paper space viewport borders and scales on a viewport layer.
Dimensioning Rules
Dimension Placement
Linear dimensions should be placed outside the outline wherever possible, aligned with the feature being dimensioned, with consistent spacing between dimension lines (usually at least 10 mm). The arc radius of angular dimensions should suit the natural curvature of the shape, with text readable from the bottom or right of the sheet. Radius dimensions start from the centre with the prefix “R”, and diameter dimensions use the prefix “Ø”.
Dimension Values
Use one unit throughout the drawing (millimetres preferred for mechanical drawings), stated once in the title block rather than on every dimension. Tolerances can be shown directly on dimensions, given as general tolerances in the title block, or referenced to a tolerance standard. Decimal places should be consistent across the drawing (usually 1 for millimetres and 3 for inches), with more places only where tighter tolerances apply.
Geometric Dimensioning and Tolerancing (GD&T)
Under ASME Y14.5, a feature control frame contains, in order, the geometric characteristic symbol, tolerance value and datum references. Datum features are identified by capital letters and establish a reference frame. Modifiers such as maximum material condition (MMC), least material condition (LMC) and regardless of feature size (RFS) control how the tolerance applies.
Common geometric characteristics include form tolerances (straightness, flatness, circularity, cylindricity), orientation tolerances (perpendicularity, parallelism, angularity), location tolerances (position, concentricity, symmetry) and runout tolerances (circular runout, total runout).
View Layout
Orthographic Projection
First angle projection is common in Europe: the object sits between the viewer and the projection plane, the right view is placed to the left of the front view, and the top view below it. Third angle projection is common in North America: the projection plane sits between the object and the viewer, the right view is on the right, and the top view above. The projection method used should be shown in the title block with the ISO standard symbol.
Sectional Views
- Full section: the cutting plane passes completely through the object along a single plane.
- Half section: one quarter of the object is removed, showing internal and external features in the same view.
- Offset section: a stepped cutting plane passes through several features that are not on one plane.
- Revolved section: the cross-section is rotated 90° and drawn over the exterior view.
- Removed section: the cross-section is drawn separately outside the view, with the cutting location clearly marked.
Auxiliary Views
Auxiliary views show features inclined to the principal projection planes: a primary auxiliary view projects from a principal view perpendicular to the inclined surface; a secondary auxiliary view projects from a primary auxiliary view to show surfaces inclined to all principal planes; and a partial auxiliary view shows only the inclined portion, reducing clutter and sheet size.
Text and Annotation Rules
Text Style
CAD drawings should use sans-serif fonts that stay legible at any scale. Where manual drafting standards apply, ISO 3098 lettering can be used. Typical text heights are 7–10 mm for title block headings, 5–7 mm for drawing titles, and 3–5 mm for dimensions and notes, so text stays legible when printed at reduced scale. Text should be horizontal or parallel to dimension lines, readable from the bottom or right of the sheet.
Note Format
General notes are grouped in one place (usually the lower left), covering general requirements, materials, surface finish and referenced standards. Local notes are placed near the relevant feature with a leader, and used sparingly only for feature-specific information. Flag notes are referenced with numbered triangular flags to consolidate repeated information. All notes are numbered in sequence for easy reference in technical discussions and correspondence.
Title Block Requirements
Required Information
A title block should include: a drawing title that clearly describes the equipment or assembly shown; a unique drawing number following the company numbering system; the current revision and revision history table; the drawing scale (such as 1:1 or 1:10), with “NTS” (not to scale) for schematics; the first or third angle projection symbol; clearly stated units of measurement; signatures and dates of the designer, checker and approver; and the company name, address and contact details.
Revision Control
The revision block records each drawing change, including revision number, description of change, date and approver. Revision clouds mark changed areas in the current revision and are usually removed in later revisions. Some drawings also show the current revision with a small triangle or similar symbol in the sheet corner for quick identification.
3D CAD Model Practices
Model Organisation
Part models should fully represent geometry, including fillets, chamfers and other features. Assembly models define the fit between parts through constraints. Configuration management allows several configurations in one model file to represent different sizes or options.
Model-Based Definition (MBD)
MBD embeds product and manufacturing information (PMI) such as dimensions, tolerances and notes directly in the 3D model, rather than relying on separate 2D drawings. Semantic PMI is machine-readable and supports automated manufacturing. ASME Y14.41 is the standard for digital product definition data practices and guides MBD implementation.
File Formats
Native formats are proprietary to each CAD package and keep the full feature history. Neutral formats such as STEP and IGES are used for cross-platform exchange. Mesh formats such as STL and OBJ are used for visualisation and additive manufacturing. 3D PDF embeds the 3D model so anyone can view it easily.
Drawing Management and Control
Document Numbering System
Systematic numbering supports efficient document management. Hierarchical numbering uses separate fields for project, discipline, equipment type and sequence number. Sequential numbering keeps separate running series for drawings, calculations and specifications. Significant numbering embeds information such as document type, originator and subject in the number.
Configuration Management
Before formal release, version control tracks drawing iterations. After release, formal revision control and approval apply. Released drawings are changed through an engineering change request process, and as-built drawings record field changes and the final installed condition.
Distribution and Access
A document management system controls electronic access to current drawings. Watermarks or stamps show copy status (controlled, for reference, superseded). External distribution procedures govern how clients and suppliers obtain drawings.
Practical CAD Practices
Clear Drawings
Keep only the views and dimensions needed, and reference related information through reference drawings. Arrange views using standard projection so spatial relationships are obvious. Keep line weights, text heights and dimension styles consistent across the drawing set. Balance information density with white space for readability.
File Management
Use a consistent, descriptive file naming convention. Set up a clearly organised folder structure. Run regular automatic backups to prevent data loss. Archive released drawings long-term in non-editable formats.
Collaboration
Use standard drawing templates for consistency across drafters and projects. Share standard symbols, blocks and part libraries. Carry out peer review and checking before release, and make sure all CAD users understand and follow the company drafting standard.
How KFE Delivers Well-Prepared Drawings
Complete Drawing Documentation
KFE can provide complete, standards-based drawing documentation to suit project needs, including GA drawings with all interface information, fully dimensioned detail drawings, assembly drawings with exploded views and assembly sequence, installation drawings with foundation details and installation requirements, and operation and maintenance drawings.
Delivery in Multiple Formats
Drawings can be delivered in the native formats of major CAD packages on request, or in neutral formats such as STEP for use across different CAD systems, along with PDF sets for easy viewing and printing, and 3D models for system integration.
Technical Support
We can help clients understand drawing content and requirements, prepare project-specific drawings, make sure drawings meet client and code requirements, and update as-built drawings after field changes.
Conclusion
CAD drawing standards provide a clear, unambiguous framework for technical communication across the full equipment life cycle, from design to decommissioning. Following established standards ensures drawings convey design intent accurately and support manufacturing, construction and maintenance.
KFE values well-prepared drawing documentation that clearly presents equipment design, supports efficient manufacturing, and provides the information needed for installation and long-term operation. To discuss the drawing requirements of your project, please contact us.
Related industry: Chemical & Pharmaceutical