Centralised lubrication should be specified as a network. List each lubrication point, grease type and grade, quantity per cycle, interval, temperature, line length/resistance and the media permitted by the equipment manufacturer. For each branch, record pipe material, fittings, metering devices and end-point evidence. Ask the manufacturer to confirm pressure, viscosity and temperature limits for the pump and distributors; pump pressure does not prove each point receives the right amount. Define manual/automatic operation, cycle start, low-level alarm, pressure confirmation, fault response, clean refilling and safe isolation. For skid-mounted units, list the pump, reservoir, filtration, controls and enclosure separately. Send the point layout and control description to KFE for coordination. Settings are decided by the maintenance engineering team; no general interval or wear reduction result is promised.
Procurement Fields
For each item, record “confirmed value, source document, open issue, reviewer, revision”. Keep measured data separate from design assumptions.
Comparison and Limits
Proposed configurations must be compared on the same media and duty. Catalogue maximums, certificates for other models or matching dimensions are not general guarantees.
Data to Submit
Submit the equipment tag, duty range, interface drawings, project requirements and a list of missing data. KFE can coordinate documents; final approval remains with the project engineers.